What is the reason why the signal amplitude of the arbitrary waveform generator is inconsistent with that of the oscilloscope?
INDUSTRIAL LCD DISPLAYS / IGBT MODULES DISTRIBUTOR

Infineon / Mitsubishi / Fuji / Semikron / Eupec / IXYS

What is the reason why the signal amplitude of the arbitrary waveform generator is inconsistent with that of the oscilloscope?

Posted Date: 2024-01-30

Arbitrary waveform generators (AWG) and oscilloscopes are two commonly used signal sources and measurement tools, both of which play an important role in electronic measurement and testing. If you find that the signal amplitude from your arbitrary waveform generator is inconsistent with your oscilloscope, there are several reasons why this may be happening. These reasons will be analyzed in detail below:

1.Range setting is incorrect :

*The range setting of the oscilloscope determines the signal amplitude range it displays. If the scope's range is set too high or too low, it may cause inaccurate readings. Please check the oscilloscope's range setting to make sure it matches the AWG's output amplitude.

2.Signal source mismatch :

*Make sure the AWG output you are using matches the oscilloscope input requirements. For example, some oscilloscopes may require a specific voltage range or impedance. Please check the documentation for the AWG and oscilloscope to ensure compatibility between them.

3.Cable and connection issues :

*Signals may be affected by cables and connectors during transmission. The length and type of cable, as well as the quality of the connectors, can all affect the amplitude of the signal. Please check all connections and cables to make sure they are all connected correctly and with high quality.

4.Internal device error :

*Even the highest quality equipment may have some errors. This may be caused by the device's internal components, temperature changes, aging, or other factors. Please refer to the AWG and oscilloscope specifications and error ranges to understand factors that may affect amplitude.

5.Calibration issues :

*In some cases, you may need to recalibrate your device. Calibration can help ensure the accuracy of your equipment, especially after prolonged use or after many moves. If you have any doubts about the accuracy of your equipment, it is recommended to contact the equipment manufacturer or the relevant calibration agency for calibration.

6.other external factors :

*There are other external factors that may affect the accuracy of the device, such as power quality, electromagnetic interference (EMI), etc. Make sure your test environment is free of anything that could interfere with device performance.

7.Software or firmware issues :

*In some cases, errors in the AWG or the oscilloscope's software or firmware can cause inaccurate signal amplitude readings. Make sure you are using the latest version of software or firmware, and check the device manufacturer's release notes or support forums to see if there are reports or solutions to this issue.

8.Use an external attenuator or amplifier :

*In some cases, you may need to use an external attenuator or amplifier to adjust the AWG's output amplitude to meet the oscilloscope's input requirements. If these external devices are used, make sure they are properly connected and in good working order.

9.Sync issues between devices :

*If you are using multiple devices simultaneously for measurements, such as using an AWG to generate waveforms and an oscilloscope to measure, make sure all devices are synchronized correctly. Time deviations between different devices can lead to inaccurate measurements.

10.human error :

*Last but not least is human error. An operator may set the wrong range or parameter due to oversight or misunderstanding, resulting in inaccurate readings. It is recommended to conduct multiple operating exercises to improve operating proficiency and reduce the possibility of human error.

To sum up, to solve the problem of inconsistency between the AWG signal and the oscilloscope, multiple factors need to be considered comprehensively and corresponding measures must be taken. From device setup, connections, and calibration to environmental conditions and human factors, every step can affect the final measurement results. By carefully troubleshooting each potential problem and taking appropriate corrective action, you should be able to accurately match the AWG and oscilloscope signal amplitude readings.